FTXG20LV1BS / RXG20L2V1B FTXG25LV1BS / RXG25L2V1B FTXG35LV1BS / RXG35L2V1B FTXG50LV1BS / RXG50L2V1B
Poff (mode arrêt) W 1.0 1.0 1.0 1.0
Rafraîchissement Psb (mode veille rafraîchissement) W 1.0 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25 0.25
Efficacité saisonnière (selon la norme EN14825) Rafraîchissement Puissance calculée kW 2.30 2.40 3.50 4.80
    Consommation énergétique annuelle kWh 94 99 175 251
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 8.52 8.50 7.00 6.70
    Condition D (20 ℃ - 27/19) Pdc kW 1.26 1.27 1.27 1.71
      puissance absorbée kW 0.09 0.09 0.10 0.17
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 13.70 13.62 13.10 10.23
    Condition C (25 ℃ - 27/19) puissance absorbée kW 0.12 0.12 0.22 0.28
      Pdc kW 1.23 1.23 1.66 2.19
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 10.28 10.15 7.58 7.83
    Condition A (35 °C - 27/19) puissance absorbée kW 0.51 0.52 0.88 1.41
      Pdc kW 2.30 2.40 3.50 4.80
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.50 4.59 3.97 3.41
    Condition B (30 ℃ - 27/19) Pdc kW 1.62 1.70 2.53 3.37
      puissance absorbée kW 0.21 0.23 0.47 0.62
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 7.59 7.26 5.39 5.46
  Chauffage (climat tempéré) Consommation énergétique annuelle kWh 639 821 913 1,519
    Puissance calculée kW 2.10 2.70 3.00 4.60
    Puiss. calor. secours nécess. sous conditions conception kW 0.30 0.52 0.39 0.78
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A++ A++ A++ A+
    TBivalente Pdh (puiss. calor. déclarée) kW 1.87 2.31 2.64 4.19
      Puissance absorbée kW 0.55 0.70 0.86 1.72
      Tbiv (température bivalente) °C -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.40 3.30 3.06 2.43
    Condition C (7 ℃) Pdh (puiss. calor. déclarée) kW 0.92 1.06 1.13 1.63
      Puissance absorbée kW 0.16 0.19 0.20 0.30
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.68 5.71 5.67 5.37
    TOL Tol (limite temp. de fonctionnement) °C -15 -15 -15 -15
      Pdh (puiss. calorifique déclarée) kW 1.68 1.95 2.56 3.19
      Puissance absorbée kW 0.62 0.79 1.06 2.14
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.69 2.47 2.41 1.49
    Condition A (-7 °C) Pdh (puis. calor. déclarée) kW 1.87 2.31 2.64 4.19
      Puissance absorbée kW 0.55 0.70 0.86 1.72
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.40 3.30 3.06 2.43
    Condition D (12 ℃) Pdh (puiss. calor. déclarée) kW 1.03 1.03 1.06 1.08
      Puissance absorbée kW 0.15 0.15 0.16 0.18
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.80 6.80 6.80 5.97
    Condition B (2 ℃) Puissance absorbée kW 0.23 0.30 0.33 0.55
      Pdh (puiss. calor. déclarée) kW 1.07 1.40 1.53 2.49
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.66 4.65 4.68 4.49
Puissance frigorifique Min. kW 1.3 (2) 1.3 (2) 1.4 (2) 1.7 (2)
  Nominale Btu/h 7,800 (2) 8,200 (2) 11,900 (2) 16,400 (2)
  Max. kW 2.8 (2) 3.0 (2) 3.8 (2) 5.3 (2)
  Min. Kcal/h 1,120 (2) 1,120 (2) 1,200 (2) 1,460 (2)
  Min. Btu/h 4,400 (2) 4,400 (2) 4,800 (2) 5,800 (2)
  Nominale Kcal/h 1,980 (2) 2,060 (2) 3,010 (2) 4,130 (2)
  Max. Btu/h 9,500 (2) 10,200 (2) 13,000 (2) 18,100 (2)
  Nominale kW 2.3 (2) 2.4 (2) 3.5 (2) 4.8 (2)
  Max. Kcal/h 2,410 (2) 2,580 (2) 3,270 (2) 4,560 (2)
Pck (mode résistance de carter) W 0.0 0.0 0.0 0.0
Efficacité nominale Consommation énergétique annuelle kWh 250.5 (0.000) 261.5 (0.000) 441 (0.000) 680 (0.000)
  Directive sur l'étiquetage énergétique Chauffage A A A A
  Nominal efficiency-=-Cop 4.59 (1) 4.59 (1) 3.97 (1) 3.53 (1)
Chauffage Heating-=-Heating cdh degradation heating 0.25 0.25 0.25 0.25
Raccords de tuyauterie Liquid DE mm 6.35 6.35 6.35 6.35
  Gaz DE mm 9.5 9.5 9.5 12.7
  Evacuation DE mm 18 18.0 18.0 18.0
  Isolation thermique Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz Tuyaux de liquide et tuyaux de gaz
Puissance calorifique Min. Btu/h 4,400 (2) 4,400 (2) 4,800 (2) 5,800 (2)
  Nominale Btu/h 8,500 (2) 11,600 (2) 13,600 (2) 19,800 (2)
  Max. Kcal/h 3,700 (2) 3,870 (2) 4,300 (2) 5,590 (2)
  Nominale Kcal/h 2,150 (2) 2,920 (2) 3,440 (2) 4,990 (2)
  Nominale kW 2.5 (2) 3.4 (2) 4.0 (2) 5.8 (2)
  Max. Btu/h 14,600 (2) 15,400 (2) 17,100 (2) 22,200 (2)
  Min. kW 1.3 (2) 1.3 (2) 1.4 (2) 1.7 (2)
  Min. Kcal/h 1,120 (2) 1,120 (2) 1,200 (2) 1,460 (2)
  Max. kW 4.3 (2) 4.5 (2) 5.0 (2) 6.5 (2)
Pto (Thermostat off) W 9.0 9.0 9.0 8.0
Puissance absorbée Rafraîchissement Min. kW 0.320 (2) 0.320 (2) 0.350 (2) 0.370 (2)
    Nom. kW 0.501 (2) 0.523 (2) 0.882 (2) 1.360 (2)
    Max. kW 0.760 (2) 0.820 (2) 1.190 (2) 1.880 (2)
  Chauffage Max. kW 1.120 (2) 1.320 (2) 1.490 (2) 2.490 (2)
    Min. kW 0.310 (2) 0.310 (2) 0.320 (2) 0.310 (2)
    Nom. kW 0.500 (2) 0.769 (2) 0.985 (2) 1.589 (2)
Saison froide incluse Oui Oui Oui Oui
Courant Courant nominal de fonctionnement - 50 Hz Chauffage A 2.8 (6), 2.7 (7), 2.6 (8) 4.4 (6), 4.2 (7), 4.0 (8) 5.5 (6), 5.3 (7), 5.1 (8) 7.4 (6), 7.1 (7), 6.8 (8)
    Rafraîchissement A 2.8 (6), 2.7 (7), 2.6 (8) 2.9 (6), 2.8 (7), 2.7 (8) 5.0 (6), 4.8 (7), 4.6 (8) 6.5 (6), 6.2 (7), 5.9 (8)
Remarques Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement Valeurs EER/COP conformes à la norme Eurovent 2012, pour utilisation hors UE uniquement
  Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20° Efficacité nominale : rafraîchissement à charge nominale 35°/27°, chauffage à charge nominale 7°/20°
  SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air)
  220V 220V 220V 220V
  230 V 230 V 230 V 230 V
  240V 240V 240V 240V