FWM01DAF FWM15DAF FWM01DAFV3 FWM15DAFV3 FWM15DAFVS FWM02DAF FWM25DAF FWM02DAFVS FWM02DAFV3 FWM25DAFV3 FWM25DAFVS FWM03DAF FWM35DAF FWM03DAFV3 FWM03DAFVS FWM35DAFVS FWM04DAF FWM04DAFV3 FWM04DAFVS FWM06DAF FWM06DAFV3 FWM06DAFVS FWM08DAF FWM08DAFV3 FWM35DAFV3 FWM10DAF FWM10DAFV3
Niveau de pression sonore Vitesse de ventilation 1 dBA         27 (6)     27 (6)     21 (6)       21 (6) 29 (6)     32 (6)     34 (6)          
  Moyen dBA     34 (6) 39 (6)         39 (6) 38 (6)       36 (6)       41 (6)     48 (6)     49 (6) 38 (6)   53 (6)
  Vitesse de ventilation 4 dBA         44 (6)     45 (6)     43 (6)       42 (6) 51 (6)     51 (6)     54 (6)          
  Bas dBA     28 (6) 33 (6)         33 (6) 29 (6)       28 (6)       32 (6)     43 (6)     41 (6) 29 (6)   43 (6)
  Vitesse de ventilation 2 dBA         33 (6)     33 (6)     29 (6)       28 (6) 38 (6)     41 (6)     43 (6)          
  Vitesse de ventilation 5 dBA         47 (6)     47 (6)     45 (6)       45 (6) 52 (6)     52 (6)     52 (6)          
  Vitesse de ventilation 3 dBA         39 (6)     39 (6)     38 (6)       36 (6) 46 (6)     45 (6)     48 (6)          
  Vitesse de ventilation 6 dBA         50 (6)     50 (6)     47 (6)       47 (6) 55 (6)     55 (6)     55 (6)          
  Haut dBA     40 (6) 44 (6)         45 (6) 43 (6)       42 (6)       51 (6)     54 (6)     55 (6) 46 (6)   61 (6)
Chute de pression d'eau Chauffage Nominale kPa 6 8       7 4         5 9       12     10     30     30  
  Rafraîchissement Nominale kPa 12 14       13 16         11 12       12     14     12     16  
Systèmes de contrôle Téléc. câblée FWEC1A, FWEC2A, FWEC3A FWEC1A, FWEC2A, FWEC3A       FWEC1A, FWEC2A, FWEC3A FWEC1A, FWEC2A, FWEC3A         FWEC1A, FWEC2A, FWEC3A FWEC1A, FWEC2A, FWEC3A       FWEC1A, FWEC2A, FWEC3A     FWEC1A, FWEC2A, FWEC3A     FWEC1A, FWEC2A, FWEC3A     FWEC1A, FWEC2A, FWEC3A  
Niveau de puissance sonore totale Vitesse de ventilation 5 dBA         52 (4)     52 (4)     50 (4)       50 (4) 57 (4)     57 (4)     57 (4)          
  Vitesse de ventilation 2 dBA         40 (4)     38 (4)     34 (4)       33 (4) 45 (4)     46 (4)     48 (4)          
  Moyen dBA     39 (4) 44 (4)         44 (4) 43 (4)       41 (4)       46 (4)     53 (4)     54 (4) 45 (4)   58 (4)
  Bas dBA     33 (4) 40 (4)         38 (4) 34 (4)       33 (4)       39 (4)     48 (4)     46 (4) 36 (4)   48 (4)
  Vitesse de ventilation 3 dBA         44 (4)     44 (4)     43 (4)       41 (4) 53 (4)     50 (4)     53 (4)          
  Vitesse de ventilation 1 dBA         32 (4)     32 (4)     26 (4)       26 (4) 36 (4)     39 (4)     39 (4)          
  Vitesse de ventilation 4 dBA         49 (4)     50 (4)     48 (4)       47 (4) 56 (4)     56 (4)     58 (4)          
  Vitesse de ventilation 6 dBA         55 (4)     55 (4)     52 (4)       52 (4) 60 (4)     60 (4)     60 (4)          
  Haut dBA     45 (4) 49 (4)         50 (4) 48 (4)       47 (4)       56 (4)     58 (4)     60 (4) 53 (4)   66 (4)
Débit d'eau Rafraîchissement Vitesse de ventilation 2 l/h         212 (1)     216 (1)     272 (1)       297 (1) 447 (1)     554 (1)     535 (1)          
    Bas l/h     169 (1) 212 (1)         216 (1) 272 (1)       297 (1)       425 (1)     535 (1)     676 (1) 336 (1)   699 (1)
    Vitesse de ventilation 3 l/h         254 (1)     267 (1)     343 (1)       400 (1) 594 (1)     683 (1)     654 (1)          
    Vitesse de ventilation 5 l/h         218 (1)     361 (1)     470 (1)       579 (1) 711 (1)     847 (1)     857 (1)          
    Vitesse de ventilation 1 l/h         174 (1)     209 (1)     245 (1)       263 (1) 336 (1)     425 (1)     457 (1)          
    Vitesse de ventilation 4 l/h         291 (1)     307 (1)     409 (1)       493 (1) 680 (1)     730 (1)     802 (1)          
    Moyen l/h     196 (1) 254 (1)         267 (1) 343 (1)       400 (1)       554 (1)     654 (1)     898 (1) 447 (1)   1,058 (1)
    Vitesse de ventilation 6 l/h         241 (1)     403 (1)     498 (1)       619 (1) 755 (1)     902 (1)     915 (1)          
    Haut l/h     250 (1) 291 (1)         307 (1) 409 (1)       493 (1)       730 (1)     802 (1)     1,138 (1) 594 (1)   1,352 (1)
  Chauffage Vitesse de ventilation 1 l/h         119 (3)     117 (3)     145 (3)       155 (3) 247 (3)     277 (3)     282 (3)          
    Vitesse de ventilation 4 l/h         154 (3)     154 (3)     222 (3)       234 (3) 409 (3)     387 (3)     406 (3)          
    Vitesse de ventilation 6 l/h         175 (3)     175 (3)     267 (3)       267 (3) 441 (3)     441 (3)     441 (3)          
    Moyen l/h     130 (3) 137 (3)         136 (3) 191 (3)       202 (3)       281 (3)     357 (3)     527 (3) 304 (3)   551 (3)
    Vitesse de ventilation 3 l/h         137 (3)     136 (3)     191 (3)       202 (3) 368 (3)     367 (3)     357 (3)          
    Haut l/h     146 (3) 154 (3)         154 (3) 222 (3)       234 (3)       334 (3)     406 (3)     610 (3) 368 (3)   643 (3)
    Vitesse de ventilation 2 l/h         120 (3)     119 (3)     156 (3)       165 (3) 304 (3)     326 (3)     311 (3)          
    Vitesse de ventilation 5 l/h         163 (3)     163 (3)     257 (3)       257 (3) 423 (3)     423 (3)     423 (3)          
    Bas l/h     115 (3) 120 (3)         119 (3) 156 (3)       165 (3)       238 (3)     311 (3)     440 (3) 247 (3)   425 (3)
  Chute de pression d'eau Chauffage Vitesse de ventilation 1 kPa         4 (3)     4 (3)     2 (3)       2 (3) 3 (3)     6 (3)     4 (3)          
      Vitesse de ventilation 4 kPa         7 (3)     6 (3)     3 (3)       4 (3) 8 (3)     10 (3)     8 (3)          
      Vitesse de ventilation 3 kPa         5 (3)     5 (3)     3 (3)       3 (3) 7 (3)     9 (3)     6 (3)          
      Vitesse de ventilation 5 kPa         7 (3)     7 (3)     5 (3)       5 (3) 9 (3)     12 (3)     9 (3)          
      Moyen kPa     4 (3) 5 (3)         5 (3) 3 (3)       3 (3)       10 (3)     6 (3)     19 (3) 12 (3)   22 (3)
      Haut kPa     4 (3) 7 (3)         6 (3) 3 (3)       4 (3)       14 (3)     8 (3)     24 (3) 16 (3)   29 (3)
      Vitesse de ventilation 2 kPa         5 (3)     4 (3)     2 (3)       2 (3) 5 (3)     7 (3)     5 (3)          
      Vitesse de ventilation 6 kPa         8 (3)     7 (3)     5 (3)       5 (3) 10 (3)     12 (3)     9 (3)          
      Bas kPa     3 (3) 4 (3)         4 (3) 2 (3)       2 (3)       8 (3)     5 (3)     14 (3) 8 (3)   14 (3)
    Rafraîchissement Moyen kPa     8 (1) 11 (1)         10 (1) 12 (1)       8 (1)       7 (1)     10 (1)     8 (1) 7 (1)   10 (1)
      Vitesse de ventilation 6 kPa         10 (1)     21 (1)     22 (1)       16 (1) 18 (1)     17 (1)     17 (1)          
      Vitesse de ventilation 2 kPa         8 (1)     7 (1)     8 (1)       5 (1) 7 (1)     7 (1)     7 (1)          
      Vitesse de ventilation 4 kPa         14 (1)     13 (1)     16 (1)       11 (1) 15 (1)     12 (1)     14 (1)          
      Haut kPa     12 (1) 14 (1)         13 (1) 16 (1)       11 (1)       12 (1)     14 (1)     12 (1) 12 (1)   16 (1)
      Vitesse de ventilation 1 kPa         6 (1)     7 (1)     6 (1)       4 (1) 4 (1)     5 (1)     5 (1)          
      Vitesse de ventilation 5 kPa         8 (1)     17 (1)     20 (1)       15 (1) 16 (1)     16 (1)     16 (1)          
      Vitesse de ventilation 3 kPa         11 (1)     10 (1)     12 (1)       8 (1) 12 (1)     11 (1)     10 (1)          
      Bas kPa     6 (1) 8 (1)         7 (1) 8 (1)       5 (1)       5 (1)     7 (1)     5 (1) 4 (1)   5 (1)
    Nom. l/h 250 291       176 409         494 594       730     803     1,138     1,362  
  Chauffage Nom. l/h 167 177       182 257         270 421       443     465     694     733  
Moteur du ventilateur Model Induction fermée, isolation de classe B, coupure thermique Induction fermée, isolation de classe B, coupure thermique       Induction fermée, isolation de classe B, coupure thermique Induction fermée, isolation de classe B, coupure thermique         Induction fermée, isolation de classe B, coupure thermique Induction fermée, isolation de classe B, coupure thermique       Induction fermée, isolation de classe B, coupure thermique     Induction fermée, isolation de classe B, coupure thermique     Induction fermée, isolation de classe B, coupure thermique     Induction fermée, isolation de classe B, coupure thermique  
  Vitesse Paliers 3 (rapide, moyenne, lente) 3 (rapide, moyenne, lente)       3 (rapide, moyenne, lente) 3 (rapide, moyenne, lente)         3 (rapide, moyenne, lente) 3 (rapide, moyenne, lente)       3 (rapide, moyenne, lente)     3 (rapide, moyenne, lente)     3 (rapide, moyenne, lente)     3 (rapide, moyenne, lente)  
Puissance frigorifique Puissance totale Nom. kW 1.14 (1) 1.48 (1)       1.56 (1) 2.00 (1)         2.33 (1) 2.60 (1)       3.23 (1)     3.81 (1)     5.23 (1)     6.16 (1)  
    Haut kW 1.46 (1) 1.69 (1)       1.79 (1) 2.38 (1)         2.87 (1) 3.46 (1)       4.26 (1)     4.67 (1)     6.64 (1)     7.88 (1)  
    Bas kW 0.99 (1) 1.24 (1)       1.26 (1) 1.58 (1)         1.73 (1) 1.96 (1)       2.48 (1)     3.11 (1)     3.93 (1)     4.07 (1)  
  Puissance sensible Bas kW 0.75 (1) 0.93 (1)       0.98 (1) 1.17 (1)         1.24 (1) 1.44 (1)       1.78 (1)     2.28 (1)     2.82 (1)     3.02 (1)  
    Haut kW 1.14 (1) 1.27 (1)       1.46 (1) 1.85 (1)         2.07 (1) 2.71 (1)       3.09 (1)     3.57 (1)     4.85 (1)     5.85 (1)  
    Nom. kW 0.90 (1) 1.11 (1)       1.22 (1) 1.54 (1)         1.66 (1) 2.02 (1)       2.42 (1)     2.87 (1)     3.80 (1)     4.57 (1)  
Échangeur de chaleur Volume d'eau L 0.5 0.5 0 0 0 0.7 0.7 1 1 1 1 1 1 1 1 1 1.4 1 1 1.4 1 1 2.1 2 1 2.1 2
  Rangées Quantité 2 2       3 3         3 2       3     3     3     3  
  Surface frontale 0.086 0.086       0.086 0.138         0.138 0.191       0.191     0.191     0.292     0.292  
  Pas des ailettes mm 1.8 1.6       1.6 1.8         1.6 1.6       1.8     1.6     2.1     2.1  
  Étages Quantité 10 10       10 10         10 10       10     10     12     12  
Échangeur de chaleur supplémentaire Volume d'eau L 0.2 0.2 0 0 0 0.2 0.3 0 0 0 0 0.3 0.4 0 0 0 0.4 0 0 0.4 0 0 0.6 1 0 0.6 1
  Rangées Quantité 1 1       1 1         1 1       1     1     1     1  
  Pas des ailettes mm 1.6 1.6       1.6 1.6         1.6 1.6       1.6     1.6     1.6     1.6  
  Surface frontale 0.068 0.068       0.068 0.110         0.110 0.152       0.152     0.152     0.243     0.243  
  Étages Quantité 8 8       8 8         8 8       8     8     10     10  
Raccords de tuyauterie Evacuation DE mm 17 17 16 16 16 17 17 16 16 16 16 17 17 16 16 16 17 16 16 17 16 16 17 16 16 17 16
  Eau Sortie 1/2" 1/2"       1/2" 1/2"         1/2" 1/2"       1/2"     1/2"     3/4"     3/4"  
Teneur en eau Serpentin primaire dm³     0.46 0.46 0.46     0.70 0.70 0.71 0.71     1.06 1.06 0.95   1.42 1.42   1.43 1.43   2.15 0.95   2.15
  Serpentin supplémentaire dm³     0.18 0.18 0.18     0.18 0.18 0.29 0.29     0.29 0.29 0.40   0.40 0.40   0.40 0.40   0.53 0.40   0.53
Puissance absorbée Vitesse de ventilation 6 kW         0.066     0.066     0.082       0.082 0.105     0.105     0.105          
  Vitesse de ventilation 1 kW         0.02     0.02     0.02       0.02 0.04     0.04     0.04          
  Haut kW     0.037 0.053         0.053 0.057       0.056       0.098     0.098     0.182 0.065   0.244
  Vitesse de ventilation 4 kW         0.05     0.05     0.06       0.06 0.09     0.09     0.09          
  Bas kW     0.02 0.03         0.02 0.03       0.03       0.04     0.05     0.09 0.04   0.11
  Moyen kW     0.03 0.04         0.04 0.04       0.04       0.06     0.07     0.13 0.05   0.17
  Vitesse de ventilation 2 kW         0.03     0.03     0.03       0.03 0.05     0.05     0.05          
  Vitesse de ventilation 5 kW         0.06     0.06     0.07       0.07 0.10     0.10     0.10          
  Vitesse de ventilation 3 kW         0.04     0.04     0.04       0.04 0.07     0.07     0.07          
  Nom. W 28 36       36 44         43 61       61     68     127     169  
  Bas W 21 25       24 29         29 37       38     47     86     109  
  Haut W 37 53       53 57         56 98       98     98     182     244  
Niveau de puissance sonore Haut dBA 45 49       50 48         47 51       56     59     60     66  
  Bas dBA 33 38       38 34         33 34       37     48     46     48  
  Nom. dBA 39 44       44 43         41 43       46     53     54     58  
Filtre à air Type Plastique Plastique       Plastique Plastique         Plastique Plastique       Plastique     Plastique     Plastique     Plastique  
Température d'eau autorisée Chauffage Max. °C     95.000 95.000 95.000     95.000 95.000 95.000 95.000     95.000 95.000 95.000   95.000 95.000   95.000 95.000   95.000 95.000   95.000
    Min. °C     5.00 5.00 5.00     5.00 5.00 5.00 5.00     5.00 5.00 5.00   5.00 5.00   5.00 5.00   5.00 5.00   5.00
  Rafraîchissement Min. °C     5 5 5     5 5 5 5     5 5 5   5 5   5 5   5 5   5
    Max. °C     95.0 95.0 95.0     95.0 95.0 95.0 95.0     95.0 95.0 95.0   95.0 95.0   95.0 95.0   95.0 95.0   95.0
Dimensions Unité Largeur mm 584 584 584 584 584 584 794 584 584 794 794 794 1,004 794 794 1,000 1,004 1,000 1,000 1,004 1,000 1,000 1,214 1,210 1,000 1,214 1,210
    Profondeur mm 224 224 224 224 224 224 224 224 224 224 224 224 224 224 224 224 224 224 224 224 224 224 249 249 224 249 249
    Hauteur mm 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535 535
Raccords de tuyauterie Serpentin supplémentaire pouce     1/2" 1/2" 1/2"     1/2" 1/2" 1/2" 1/2"     1/2" 1/2" 1/2"   1/2" 1/2"   1/2" 1/2"   1/2" 1/2"   1/2"
  Serpentin primaire pouce     1/2" 1/2" 1/2"     1/2" 1/2" 1/2" 1/2"     1/2" 1/2" 1/2"   1/2" 1/2"   1/2" 1/2"   3/4 " 1/2"   3/4 "
Caisson Colour Plastique + tôle Plastique + tôle       Plastique + tôle Plastique + tôle         Plastique + tôle Plastique + tôle       Plastique + tôle     Plastique + tôle     Plastique + tôle     Plastique + tôle  
Weight Unité kg 15 16 16.5 16.5 16.5 16 20 16.9 16.9 21.4 21.4 20 25 22.1 22.1 26.3 25 26.4 26.4 25 26.6 26.6 34 35.4 26.3 34 35.4
Ventilateur Débit d'air Vitesse de ventilation 3 m³/h         261     261     334       332 628     637     593          
    Vitesse de ventilation 2 m³/h         205     205     238       237 444     490     460          
    Vitesse de ventilation 4 m³/h         330     327     432       431 798     690     763          
    Vitesse de ventilation 1 m³/h         196     196     211       211 316     356     389          
    Vitesse de ventilation 5 m³/h         380     380     528       528 855     855     855          
    Moyen m³/h 225 261 225 261   261 334   261 334   332 444 332     490 490   593 593   765 765 444 1,007 1,007
    Vitesse de ventilation 6 m³/h         450     450     579       579 938     938     938          
    Low m³/h 174 205 174 205   205 238   205 238   238 316 237     356 356   460 460   565 565 316 636 636
    High m³/h 307 330 307 330   327 432   327 432   431 628 431     690 690   763 763   998 998 628 1,362 1,362
  Type 1 1       1 2         2 2       2     2     2     2  
Puissance frigorifique (conditions standards) Puissance totale (4 tuyaux) Vitesse de ventilation 6 kW         1.33 (1)     2.28 (1)     2.82 (1)       3.53 (1) 4.30 (1)     5.16 (1)     5.23 (1)          
    Vitesse de ventilation 1 kW         1.00 (1)     1.20 (1)     1.41 (1)       1.51 (1) 1.92 (1)     2.44 (1)     2.63 (1)          
    Vitesse de ventilation 3 kW         1.44 (1)     1.52 (1)     1.96 (1)       2.29 (1) 3.40 (1)     3.92 (1)     3.74 (1)          
    Bas kW     0.97 (1) 1.22 (1)         1.24 (1) 1.55 (1)       1.70 (1)       2.44 (1)     3.06 (1)     3.84 (1) 1.92 (1)   3.96 (1)
    Haut kW     1.42 (1) 1.64 (1)         1.74 (1) 2.32 (1)       2.81 (1)       4.16 (1)     4.57 (1)     6.46 (1) 3.36 (1)   7.64 (1)
    Vitesse de ventilation 2 kW         1.22 (1)     1.24 (1)     1.55 (1)       1.70 (1) 2.55 (1)     3.17 (1)     3.06 (1)          
    Vitesse de ventilation 5 kW         1.21 (1)     2.05 (1)     2.67 (1)       3.30 (1) 4.06 (1)     4.84 (1)     4.91 (1)          
    Moyen kW     1.11 (1) 1.44 (1)         1.52 (1) 1.96 (1)       2.29 (1)       3.17 (1)     3.74 (1)     5.10 (1) 2.54 (1)   5.99 (1)
    Vitesse de ventilation 4 kW         1.64 (1)     1.74 (1)     2.32 (1)       2.81 (1) 3.88 (1)     4.16 (1)     4.57 (1)          
  Puissance sensible (4 tuyaux) Vitesse de ventilation 5 kW         1.21 (1)     1.65 (1)     2.16 (1)       2.32 (1) 3.30 (1)     3.81 (1)     3.81 (1)          
    Vitesse de ventilation 2 kW         0.91 (1)     0.96 (1)     1.14 (1)       1.21 (1) 1.96 (1)     2.36 (1)     2.23 (1)          
    Vitesse de ventilation 6 kW         1.33 (1)     1.90 (1)     2.31 (1)       2.47 (1) 3.53 (1)     4.10 (1)     4.10 (1)          
    Bas kW     0.73 (1) 0.91 (1)         0.96 (1) 1.14 (1)       1.21 (1)       1.74 (1)     2.23 (1)     2.73 (1) 1.40 (1)   2.91 (1)
    Vitesse de ventilation 1 kW         0.84 (1)     0.92 (1)     1.03 (1)       1.08 (1) 1.40 (1)     1.74 (1)     1.92 (1)          
    Vitesse de ventilation 4 kW         1.22 (1)     1.41 (1)     1.79 (1)       2.01 (1) 3.13 (1)     2.99 (1)     3.47 (1)          
    Moyen kW     0.87 (1) 1.07 (1)         1.18 (1) 1.50 (1)       1.62 (1)       2.36 (1)     2.80 (1)     3.67 (1) 1.96 (1)   4.40 (1)
    Haut kW     1.10 (1) 1.22 (1)         1.41 (1) 1.79 (1)       2.01 (1)       2.99 (1)     3.47 (1)     4.67 (1) 2.61 (1)   5.61 (1)
    Vitesse de ventilation 3 kW         1.07 (1)     1.18 (1)     1.50 (1)       1.62 (1) 2.61 (1)     2.98 (1)     2.81 (1)          
  Puissance latente (4 tuyaux) Haut kW     0.32 (1) 0.42 (1) 0.00 (1)     0.38 (1) 0.33 (1) 0.53 (1) 0.51 (1)     0.80 (1) 1.06 (1) 0.77 (1)   1.17 (1) 1.06 (1)   1.19 (1) 1.13 (1)   1.79 (1) 0.75 (1)   2.03 (1)
Puissance calorifique 4 tuyaux Haut kW 1.90 (2) 2.02 (2)       2.01 (2) 2.92 (2)         3.08 (2) 4.80 (2)       5.05 (2)     5.30 (2)     7.91 (2)     8.35 (2)  
    Moyen kW 1.70 (2) 1.78 (2)       1.78 (2) 2.53 (2)         2.68 (2) 3.96 (2)       4.25 (2)     4.65 (2)     6.83 (2)     7.14 (2)  
    Bas kW 1.50 (2) 1.56 (2)       1.56 (2) 2.06 (2)         2.18 (2) 3.21 (2)       3.60 (2)     4.04 (2)     5.69 (2)     5.50 (2)  
Puissance calorifique (conditions standards) Puissance (4 tuyaux) Vitesse de ventilation 5 kW         1.86 (3)     1.86 (3)     2.93 (3)       2.93 (3) 4.83 (3)     4.83 (3)     4.83 (3)          
    Moyen kW     1.49 (3) 1.56 (3)         1.56 (3) 2.18 (3)       2.31 (3)       3.22 (3)     4.07 (3)     6.02 (3) 3.47 (3)   6.29 (3)
    Vitesse de ventilation 3 kW         1.56 (3)     1.56 (3)     2.18 (3)       2.31 (3) 4.20 (3)     3.82 (3)     4.07 (3)          
    Vitesse de ventilation 6 kW         2.00 (3)     2.00 (3)     3.06 (3)       3.06 (3) 5.04 (3)     5.04 (3)     5.04 (3)          
    Bas kW     1.31 (3) 1.36 (3)         1.36 (3) 1.78 (3)       1.88 (3)       2.73 (3)     3.55 (3)     5.02 (3) 2.82 (3)   4.85 (3)
    Vitesse de ventilation 2 kW         1.36 (3)     1.36 (3)     1.78 (3)       1.88 (3) 3.47 (3)     3.22 (3)     3.55 (3)          
    Vitesse de ventilation 1 kW         1.36 (3)     1.33 (3)     1.66 (3)       1.77 (3) 2.82 (3)     2.73 (3)     3.23 (3)          
    Haut kW     1.66 (3) 1.76 (3)         1.76 (3) 2.53 (3)       2.68 (3)       3.82 (3)     4.64 (3)     6.97 (3) 4.20 (3)   7.35 (3)
    Vitesse de ventilation 4 kW         1.76 (3)     1.76 (3)     2.53 (3)       2.68 (3) 4.67 (3)     4.42 (3)     4.64 (3)          
Isolation antivibration Classe 1 auto-extinguible Classe 1 auto-extinguible       Classe 1 auto-extinguible Classe 1 auto-extinguible         Classe 1 auto-extinguible Classe 1 auto-extinguible       Classe 1 auto-extinguible     Classe 1 auto-extinguible     Classe 1 auto-extinguible     Classe 1 auto-extinguible  
Dispositif de chauffage électrique Fréquence Hz     50 50 50     50 50 50 50     50 50 50   50 50   50 50   50 50   50
  Courant A     4.5 6.8 6.8     6.8 6.8 7.3 7.3     7.3 7.3 9.1   9.1 9.1   9.1 9.1   13.6 9.1   13.6
  Puissance absorbée kW     1.0 1.5 1.5     1.5 1.5 1.6 1.6     1.6 1.6 2.0   2.0 2.0   2.0 2.0   3.0 2.0   3.0
  Tension V     230 230 230     230 230 230 230     230 230 230   230 230   230 230   230 230   230
Entrée de courant Vitesse de ventilation 2 A         0.11     0.11     0.14       0.14 0.29     0.29     0.29          
  Vitesse de ventilation 3 A         0.14     0.14     0.20       0.20 0.40     0.40     0.40          
  Vitesse de ventilation 5 A         0.25     0.25     0.31       0.31 0.42     0.42     0.42          
  Moyen A 0.13 0.16 0.11 0.14   0.16 0.21   0.14 0.20   0.20 0.29 0.20     0.29 0.29   0.31 0.28   0.57 0.57 0.29 0.76 0.78
  Haut A 0.17 0.24 0.16 0.20   0.24 0.26   0.20 0.27   0.25 0.44 0.27     0.44 0.40   0.43 0.39   0.82 0.80 0.40 1.10 1.07
  Vitesse de ventilation 6 A         0.29     0.29     0.36       0.36 0.47     0.47     0.47          
  Vitesse de ventilation 4 A         0.20     0.20     0.27       0.27 0.40     0.40     0.40          
  Bas A 0.10 0.12 0.09 0.11   0.11 0.14   0.11 0.14   0.14 0.19 0.14     0.19 0.19   0.22 0.19   0.39 0.39 0.19 0.50 0.54
  Vitesse de ventilation 1 A         0.08     0.08     0.11       0.11 0.19     0.19     0.19          
Section de câble requise mm² 1 1 0.5 0.5 0.5 1 1 0.5 0.5 0.5 0.5 1 1 0.5 0.5 0.5 1 0.5 0.5 1 0.5 0.5 1 0.5 0.5 1 0.5
Courant absorbé maximal A     0.170 0.240 0.300     0.300 0.240 0.250 0.400     0.250 0.400 0.460   0.440 0.460   0.440 0.460   0.800 0.440   1.120
Fusibles requis A 0.5 0.5       0.5 0.5         0.5 0.5       0.5     0.5     1     2  
Alimentation électrique Fréquence Hz 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50   50 50 50 50 50 50
  Tension V 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230 230   230 230 230 230 230 230
  Phase 1~ 1~       1~ 1~         1~ 1~       1~     1~     1~     1~  
Remarques Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K. Rafraîchissement : 4 tuyaux : air 27 °CBS, 19 °CBH ; eau à l'entrée 7 °C ; eau en sortie 12 °C Rafraîchissement : temp. intérieure  27 °CBS, 19 °CBH ; temp. eau en entrée 7 °C, élévation de la température de l'eau 5 K.
  Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K. Chauffage : 4 tuyaux : air 20 °CBS ; eau à l'entrée 70 °C ; eau en sortie 60 °C Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 45 °C, chute de température de l'eau 5 K.
  La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K. La consommation électrique du moteur de la vanne est de 5 W (pic). Cette valeur est uniquement obtenue pendant l'ouverture. Chauffage : temp. intérieure 20°C BS, 15°C BH ; temp. de l'eau à l'entrée 65°C, chute de température de l'eau 10K.
FCEER     E E E     E E E E     D D E   D D   D D   E E   E
FCCOP     E E E     E E E E     E E D   D D   D D   E D   E
Échangeur de chaleur Type       Serpentin à ailettes transversales Serpentin à ailettes transversales Serpentin à ailettes transversales     Serpentin à ailettes transversales Serpentin à ailettes transversales Serpentin à ailettes transversales Serpentin à ailettes transversales     Serpentin à ailettes transversales Serpentin à ailettes transversales Serpentin à ailettes transversales   Serpentin à ailettes transversales Serpentin à ailettes transversales   Serpentin à ailettes transversales Serpentin à ailettes transversales   Serpentin à ailettes transversales Serpentin à ailettes transversales   Serpentin à ailettes transversales
  Rangées Quantité       2 2 2     3 3 2 2     3 3 2   3 3   3 3   3 2   3
  Ailettes Type       Aluminium Aluminium Aluminium     Aluminium Aluminium Aluminium Aluminium     Aluminium Aluminium Aluminium   Aluminium Aluminium   Aluminium Aluminium   Aluminium Aluminium   Aluminium
  Tube material       Cuivre Cuivre Cuivre     Cuivre Cuivre Cuivre Cuivre     Cuivre Cuivre Cuivre   Cuivre Cuivre   Cuivre Cuivre   Cuivre Cuivre   Cuivre
Échangeur de chaleur supplémentaire Rangées Quantité       1 1 1     1 1 1 1     1 1 1   1 1   1 1   1 1   1
Filtre à air Type       Filet en polypropylène Filet en polypropylène Filet en polypropylène     Filet en polypropylène Filet en polypropylène Filet en polypropylène Filet en polypropylène     Filet en polypropylène Filet en polypropylène Filet en polypropylène   Filet en polypropylène Filet en polypropylène   Filet en polypropylène Filet en polypropylène   Filet en polypropylène Filet en polypropylène   Filet en polypropylène
Ventilateur Type       Centrifuge Centrifuge Centrifuge     Centrifuge Centrifuge Centrifuge Centrifuge     Centrifuge Centrifuge Centrifuge   Centrifuge Centrifuge   Centrifuge Centrifuge   Centrifuge Centrifuge   Centrifuge
  Quantité       1 1 1     1 1 2 2     2 2 2   2 2   2 2   2 2   2
Insulation material     Polyéthylène à cellules fermées Polyéthylène à cellules fermées Polyéthylène à cellules fermées     Polyéthylène à cellules fermées Polyéthylène à cellules fermées Polyéthylène à cellules fermées Polyéthylène à cellules fermées     Polyéthylène à cellules fermées Polyéthylène à cellules fermées Polyéthylène à cellules fermées   Polyéthylène à cellules fermées Polyéthylène à cellules fermées   Polyéthylène à cellules fermées Polyéthylène à cellules fermées   Polyéthylène à cellules fermées Polyéthylène à cellules fermées   Polyéthylène à cellules fermées
Alimentation électrique Type       230 / 1 / 50 230 / 1 / 50 230 / 1 / 50     230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50     230 / 1 / 50 230 / 1 / 50 230 / 1 / 50   230 / 1 / 50 230 / 1 / 50     230 / 1 / 50   230 / 1 / 50 230 / 1 / 50   230 / 1 / 50
  Phase       1~ 1~ 1~     1~ 1~ 1~ 1~     1~ 1~ 1~   1~ 1~     1~   1~ 1~   1~
Dispositif de chauffage électrique Type       230 / 1 / 50 230 / 1 / 50 230 / 1 / 50     230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50     230 / 1 / 50 230 / 1 / 50 230 / 1 / 50   230 / 1 / 50 230 / 1 / 50   230 / 1 / 50 230 / 1 / 50   230 / 1 / 50 230 / 1 / 50   230 / 1 / 50
  Phase       1 1 1     1 1 1 1     1 1 1   1 1   1 1   1 1   1
Remarques     Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741     Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741     Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741   Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741   Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741   Niveau de puissance sonore conforme à la norme ISO3741 Niveau de puissance sonore conforme à la norme ISO3741   Niveau de puissance sonore conforme à la norme ISO3741
      SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air)     SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air)     SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air)   SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air)   SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air)   SL : Très faible niveau sonore de ventilation (réglage du débit d’air) SL : Très faible niveau sonore de ventilation (réglage du débit d’air)   SL : Très faible niveau sonore de ventilation (réglage du débit d’air)
      Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.     Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.     Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.   Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.   Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.   Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité. Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.   Le niveau de pression sonore est mesuré à l'aide d'un microphone placé à 1 m de l'unité.