| EHBH16CB3V / ERHQ014BAW17 | EHBH16CB9W / ERHQ014BAW17 | ||||
|---|---|---|---|---|---|
| COP | 4.24 (1), 3.22 (2) | 4.24 (1), 3.22 (2) | |||
| Puissance calorifique | Nom. | kW | 14.5 (1), 13.6 (2) | 14.5 (1), 13.6 (2) | |
| Puissance absorbée | Chauffage | Nom. | kW | 3.42 (1), 4.21 (2) | 3.42 (1), 4.21 (2) |
| Remarques | (1) - Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | (1) - Condition 1 : rafraîchissement Ta 35 °C - LWE 18 °C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 35 °C (DT = 5 °C) | |||
| (2) - Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) | (2) - Condition 2 : rafraîchissement Ta 35 °C - LWE 7°C (DT = 5 °C) ; chauffage Ta BS/BH 7 °C/6 °C - LWC 45 °C (DT = 5 °C) | ||||
| (3) - Tamb 35 °C - LWE 7 °C (DT=5 °C) | (3) - Tamb 35 °C - LWE 7 °C (DT=5 °C) | ||||
| (4) - Tamb 35 °C - LWE 18°C (DT=5 °C) | (4) - Tamb 35 °C - LWE 18°C (DT=5 °C) | ||||
| (5) - BS/BH 7 °C/6 °C-LWC 35 °C(DT=5 °C) | (5) - BS/BH 7 °C/6 °C-LWC 35 °C(DT=5 °C) | ||||
| (6) - BS/BH 7 °C/6 °C - LWC 45 °C(Dt=5 °C) | (6) - BS/BH 7 °C/6 °C - LWC 45 °C(Dt=5 °C) | ||||