EHSH04P30DA / ERGA04DAV3 EHSH08P30DA / ERGA06DAV3A EHSH08P50DA / ERGA06DAV3A EHSH08P50DA / ERGA06DAV3 EHSH08P30DA / ERGA06DAV3 EHSH08P50DA / ERGA08DAV3A EHSH08P30DA / ERGA08DAV3A EHSH08P30DA / ERGA08DAV3 EHSH08P50DA / ERGA08DAV3
Binnenunit EHSH04P30D EHSH08P30D EHSH08P50D EHSH08P50D EHSH08P30D EHSH08P50D EHSH08P30D EHSH08P30D EHSH08P50D
Buitenunit ERGA04DAV3 ERGA06DAV3A ERGA06DAV3A ERGA06DAV3 ERGA06DAV3 ERGA08DAV3A ERGA08DAV3A ERGA08DAV3 ERGA08DAV3
Verwarmingscapaciteit Nom. kW 4.30 (1), 4.60 (2) 5.90 (2), 6.00 (1) 5.90 (2), 6.00 (1) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2)
Opgenomen vermogen Verwarmen Nom. kW 0.850 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2)
Heat up time from 10°C to 50°C hr 1h31min     2h57min 1h31min     1h31min 2h57min
COP 5.10 (1), 3.65 (2) 3.50 (2), 4.85 (1) 3.50 (2), 4.85 (1) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 3.50 (2), 4.60 (1) 3.50 (2), 4.60 (1) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2)
Pomp Type   Grundfos UPM3K 25-75 CHBL     Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL     Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL
  Nominale externe statische druk unit Verwarmen kPa 66.0 (1), 65.0 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 38.7 (2), 42.7 (1) 38.7 (2), 42.7 (1) 42.7 (1), 38.7 (2) 42.7 (1), 38.7 (2)
Warmtewisselaar waterzijde Waterdebiet Verwarmen Nom. l/min 12.3 (1), 13.2 (2) 16.9 (2), 17.2 (1) 16.9 (2), 17.2 (1) 17.2 (1), 16.9 (2) 17.2 (1), 16.9 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2)
Algemeen Productbeschrijving Lucht/water-warmtepomp   Ja Ja Ja Ja Ja Ja Ja Ja Ja
    Glycol/water-warmtepomp   Nee Nee Nee Nee Nee Nee Nee Nee Nee
    Verwarming combinatie warmtepomp   Ja Ja Ja Ja Ja Ja Ja Ja Ja
    Lagetemperatuurswarmtepomp   Nee Nee Nee Nee Nee Nee Nee Nee Nee
    Ingebouwde hulpverwarming   Nee Nee Nee Nee Nee Nee Nee Nee Nee
    Water/water-warmtepomp   Nee Nee Nee Nee Nee Nee Nee Nee Nee
  LW(A) geluidsvermogensniveau (volgens EN14825) Binnen dB(A) 39 39 39 39 39 39 39 39 39
LW(A) geluidsvermogensniveau (volgens EN14825) Buiten dB(A) 58 60 60 60 60 62 62 62 62
Ecodesign geluidsconditie en energielabel Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825 Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825 Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825 Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825 Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825 Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825 Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825 Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825 Geluidsvermogen in verwarmingsmodus, gemeten volgens EN12102 onder voorwaarden van EN14825
Algemene verwarming Lucht/water-unit Nominaal luchtdebiet (buiten) m³/u 2,280 27,770 27,770 2,520 2,520 2,770 2,770 2,770 2,770
  Andere Capaciteitsregeling   Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter
    Poff (uitgeschakelde stand) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
    Psb (in stand-by) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
    Pto (thermostaat uit) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
  Ingebouwde hulpverwarming Type stroomvoorziening   Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch
Verwarming van sanitair warm water Algemeen Aangegevens belastingprofiel   L L XL XL L XL L L XL
    Functie voor verwarmen van water tijdens daluren   Ja Ja Ja Ja Ja Ja Ja Ja Ja
  Gematigd klimaat AEC (jaarlijks stroomverbruik) kWu 951 1,074 1,715 1,584 951 1,715 1,074 951 1,584
    Ƞwh (waterverwarmingsrendement) % 108 95 98 106 108 98 95 108 106
    Qelec (dagelijks stroomverbruik) kWu 4.500 5.128 8.037 7.426 4.500 8.037 5.128 4.500 7.426
    Energierendementsklasse waterverwarming   A A   A A   A A A
  Koud klimaat AEC (jaarlijks stroomverbruik) kWu 1,366 1,366 2,260 2,260 1,366 2,260 1,366 1,366 2,260
    Ƞwh (waterverwarmingsrendement) % 75 75 75 75 75 75 75 75 75
    Qelec (dagelijks stroomverbruik) kWu 6.454 6.454 10.520 10.520 6.454 10.520 6.454 6.454 10.520
  Warm klimaat AEC (jaarlijks stroomverbruik) kWu 940 940 1,436 1,436 940 1,436 940 940 1,436
    Ƞwh (waterverwarmingsrendement) % 109 109 117 117 109 117 109 109 117
    Qelec (dagelijks stroomverbruik) kWu 4.513 4.513 6.766 6.766 4.513 6.766 4.513 4.513 6.766
Centrale verwarming Wateruitlaat gematigd klimaat 55°C Algemeen SCOP   3.26 3.25 3.25 3.26 3.26 3.27 3.27 3.32 3.32
      Jaarlijks energieverbruik kWu 3,806 4,456 4,456 4,441 4,441 4,731 4,731 4,975 4,975
      Seizoensrendement van verwarming % 127 127 127 127 127 128 128 130 130
      Pnominaal bij -10°C kW 6.0 7 7 7.0 7.0 8 8 8.0 8.0
      Seizoensefficiëntieklasse verwarming   A++ A++ A++ A++ A++ A++ A++ A++ A++
    A-conditie (-7°C DB/-8°C NB) Cdh (degradatie-verwarming)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   1.97 1.98 1.98 1.98 1.98 198.00 198.00 1.96 1.96
      Pdh kW 5.3 5.9 5.9 5.9 5.9 5.9 5.9 6.9 6.9
      PERd % 79.0 79.0 79.0 79.0 79.0 79.0 79.0 78.0 78.0
    B-conditie (-2°C DB/1°C NB) Cdh (degradatie-verwarming)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.23 3.16 3.16 3.16 3.16 3.18 3.18 3.20 3.20
      Pdh kW 3.3 3.9 3.9 3.9 3.9 4.1 4.1 4.4 4.4
      PERd % 129.0 126.0 126.0 126.0 126.0 127.0 127.0 128.0 128.0
    C-conditie (7°C DB/6°C NB) Cdh (degradatie-verwarming)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.40 4.49 4.49 4.49 4.49 4.54 4.54 4.64 4.64
      Pdh kW 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.3 3.3
      PERd % 176.0 180.0 180.0 180.0 180.0 182.0 182.0 186.0 186.0
    D-conditie (12°C DB/11°C NB) Cdh (degradatie-verwarming)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.10 6.16 6.16 6.22 6.22
      Pdh kW 3.3 3.3 3.3 3.3 3.3 3.7 3.7 4.1 4.1
      PERd % 244.0 244.0 244.0 244.0 244.0 246.0 246.0 249.0 249.0
    Tol (min./max. bedrijfstemperatuur) COPd   1.37 1.43 1.43 1.53 1.53 1.43 1.43 1.64 1.64
      Pdh kW 4.0 4.5 4.5 5.4 5.4 4.5 4.5 7.1 7.1
      PERd % 55.0 57.0 57.0 61.0 61.0 57.0 57.0 66.0 66.0
      TOL °C -10 -10 -10 -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55 55 55 55
    Tbiv (bivalente temperatuur) COPd   1.97 2.12 2.12 2.12 2.12 2.18 2.18 1.90 1.90
      Pdh kW 5.3 6.1 6.1 6.1 6.1 6.4 6.4 7.5 7.5
      PERd % 79.0 85.0 85.0 85.0 85.0 87.0 87.0 76.0 76.0
      Tbiv °C -7 -6 -6 -6 -6 -6 -6 -8 -8
  Wateruitlaat koud klimaat 55°C Algemeen Jaarlijks energieverbruik kWu 4,468 5,325 5,325 5,300 5,300 7,066 7,066 6,886 6,886
      Seizoensrendement van verwarming % 107 108 108 109 109 109 109 112 112
      Pnominaal bij -22°C kW 5 6 6 6 6 8 8 8 8
  Wateruitlaat warm klimaat 55°C Algemeen Jaarlijks energieverbruik kWu 1,660 1,858 1,858 1,858 1,858 1,983 1,983 2,213 2,213
      Ƞs (seizoensefficiëntie ruimteverwarming) % 148 158 158 158 158 159 159 161 161
      Pnominaal bij 2°C kW 5 6 6 6 6 6 6 7 7
  Wateruitlaat gematigd klimaat 35°C Algemeen SCOP   4.48 4.47 4.47 4.47 4.47 4.56 4.56 4.56 4.56
      Jaarlijks energieverbruik kWu 2,766 3,233 3,233 3,233 3,233 3,625 3,625 3,625 3,625
      Ƞs (seizoensefficiëntie ruimteverwarming) % 176 176 176 176 176 179 179 179 179
      Pnominaal -10°C kW 6.0 7 7 7.0 7.0 8 8 8.0 8.0
      Qhe jaarl. energieverbruik (GCV) Gj 1 1 1 1 1 1 1 1 1
      Seizoensrendementsklasse verwarming   A++ A++ A++ A++ A++ A++ A++ A++ A++
    A-conditie (-7°C DB/-8°C NB) COPd   2.90 2.86 2.86 2.86 2.86 2.77 2.77 2.77 2.77
      Pdh kW 5.5 6.0 6.0 6.0 6.0 7.0 7.0 7.0 7.0
      PERd % 116.0 114.0 114.0 114.0 114.0 111.0 111.0 111.0 111.0
    B-conditie (2°C DB/1°C NB) Cdh (degradatie-verwarming)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.33 4.25 4.25 4.25 4.25 4.35 4.35 4.35 4.35
      Pdh kW 3.3 3.9 3.9 3.9 3.9 4.2 4.2 4.2 4.2
      PERd % 173.0 170.0 170.0 170.0 170.0 174.0 174.0 174.0 174.0
    C-conditie (7°C DB/6°C NB) Cdh (degradatie-verwarming)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.19 6.30 6.30 6.30 6.30 6.49 6.49 6.49 6.49
      Pdh kW 3.2 3.2 3.2 3.2 3.2 3.3 3.3 3.3 3.3
      PERd % 248.0 252.0 252.0 252.0 252.0 260.0 260.0 260.0 260.0
    D-conditie (12°C DB/11°C NB) Cdh (reductie van verwarming)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.78 7.78 7.78 7.78 7.78 8.52 8.52 8.52 8.52
      Pdh kW 3.3 3.3 3.3 3.3 3.3 3.9 3.9 3.9 3.9
      PERd % 311.0 311.0 311.0 311.0 311.0 341.0 341.0 341.0 341.0
    TOL (bedrijfstemperatuur) COPd   2.56 2.49 2.49 2.49 2.49 2.41 2.41 2.41 2.41
      Pdh kW 5.2 6.0 6.0 6.0 6.0 6.9 6.9 6.9 6.9
      PERd % 102.0 100.0 100.0 100.0 100.0 96.0 96.0 96.0 96.0
      TOL °C -10 -10 -10 -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35 35 35 35
    Tbiv (bivalente temperatuur) COPd   2.90 3.07 3.07 2.49 2.49 2.66 2.66 2.66 2.66
      Pdh kW 5.5 6.1 6.1 6.0 6.0 7.5 7.5 7.5 7.5
      PERd % 116.0 123.0 123.0 100.0 100.0 106.0 106.0 106.0 106.0
      Tbiv °C -7 -6 -6 -6 -6 -8 -8 -8 -8
    Nom. bijkomend verwarmingsvermogen Psup (bij Tontwerp -10°C) kW 0.8                
  Wateruitlaat koud klimaat 35°C Algemeen Jaarlijks energieverbruik kWu 3,230 3,749 3,749 3,749 3,749 5,052 5,052 5,034 5,034
      Ƞs (seizoensefficiëntie ruimteverwarming) % 150 155 155 155 155 153 153 154 154
      Pnominaal bij -22°C kW 5 6 6 6 6 8 8 8 8
  Wateruitlaat warm klimaat 35°C Algemeen Jaarlijks energieverbruik kWu 1,139 1,276 1,276 1,276 1,276   1,437 1,437 1,437
      Ƞs (seizoensefficiëntie ruimteverwarming) % 241 248 248 248 248   257 257 257
      Pnominaal bij 2°C kW 5 6 6 6 6   7 7 7
Opmerkingen Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C)
  Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C)