Tabel met technische gegevens voor FHQ-CB / RXS-L

FHQ50CBVEB / RXS50L2V1B FHQ60CBVEB / RXS60L2V1B
Poff (uitgeschakeld) W 15.0 15.0
Koelen Psb (koeling in stand-by) W 15.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Eurovent Geluidsvermogenniveau binnenunit Koelen Nom. dBA 54 54
  Sound power level outdoor Cooling Nom. dBA 62 62
Seizoensrendement (volgens EN14825) Koelen Pdesign kW 5.00 5.70
    Jaarlijks energieverbruik kWu 298 332
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.87 6.02
    D voorwaarden (20℃ - 27/19) Pdc kW 2.18 2.41
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.67 10.93
    C voorwaarden (25℃ - 27/19) Pdc kW 2.37 2.70
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.73 7.78
    A voorwaarden (35°C - 27/19) Pdc kW 5.00 5.70
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.27 3.31
    B voorwaarden (30℃ - 27/19) Pdc kW 3.69 4.20
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.14 5.17
  Verwarming (gematigd klimaat) Jaarlijks energieverbruik kWu 1,578 1,705
    Pdh verwarmingsvermogen bij -10° kW 3.85 4.08
    Pdesign kW 4.35 4.71
    Min. vermogen backupverwarming bij ontwerpvoorwdn kW 0.50 0.63
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A A
    TBivalent Pdh (verwarmingsvermogen) kW 3.85 4.17
      Tbiv (bivalente temperatuur) °C -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.24 2.31
    C voorwaarden (7℃) Pdh (verwarmingsvermogen) kW 1.54 1.63
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.85 4.71
    TOL TOL (bedrijfstemperatuur) °C -15 -15
      Pdh (beschikbaar verwarmingsvermogen) kW 3.86 3.92
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.86 1.84
    A voorwaarden (-7°C) Pdh (verwarmingsvermogen) kW 3.85 4.17
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.24 2.31
    D voorwaarden (12℃) Pdh (verwarmingsvermogen) kW 1.80 1.74
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.04 5.96
    B voorwaarden (2°C) Pdh (verwarmingsvermogen) kW 2.33 2.54
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.03 4.06
Pck (verwarming krukkast) W 0.0 0.0
Verwarmen Heating-=-Heating cdh degradation heating 0.25 0.25
Pto (Thermostat off) W 10.0 10.0
Koud seizoen inbegrepen Ja Ja