Tabel met technische gegevens voor FTXS-G / RXS-L

FTXS60GV1B / RXS60L2V1B
Poff (uitgeschakeld) W 15.0
Koelen Psb (koeling in stand-by) W 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Seizoensrendement (volgens EN14825) Koelen Pdesign kW 6.00
    Jaarlijks energieverbruik kWu 376
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.58
    D voorwaarden (20℃ - 27/19) Pdc kW 2.28
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.00
    C voorwaarden (25℃ - 27/19) Pdc kW 2.84
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.12
    A voorwaarden (35°C - 27/19) Pdc kW 6.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.00
    B voorwaarden (30℃ - 27/19) Pdc kW 4.42
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.73
  Verwarming (gematigd klimaat) Jaarlijks energieverbruik kWu 1,728
    Pdesign kW 4.80
    Min. vermogen backupverwarming bij ontwerpvoorwdn kW 0.68
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A
    TBivalent Pdh (verwarmingsvermogen) kW 4.25
      Tbiv (bivalente temperatuur) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.22
    C voorwaarden (7℃) Pdh (verwarmingsvermogen) kW 1.65
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.91
    TOL TOL (bedrijfstemperatuur) °C -15
      Pdh (beschikbaar verwarmingsvermogen) kW 3.91
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.81
    A voorwaarden (-7°C) Pdh (verwarmingsvermogen) kW 4.25
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.22
    D voorwaarden (12℃) Pdh (verwarmingsvermogen) kW 1.95
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.12
    B voorwaarden (2°C) Pdh (verwarmingsvermogen) kW 2.58
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.11
Koelcapaciteit Nom. Btu/u 20,500
  Min. kW 1.7
  Nom. kcal/u 5,160
  Max. kW 6.7
  Min. kcal/u 1,460
  Min. Btu/u 5,800
  Nom. kW 6.0
  Max. Btu/u 22,900
  Max. kcal/u 5,760
Pck (verwarming krukkast) W 0.0
Nominaal energierendement Jaarlijks energieverbruik kWu 995 (0.000)
  Richtlijn Energielabels Verwarming B
  Nominal efficiency-=-Cop 3.02
Verwarmen Heating-=-Heating cdh degradation heating 0.25
Leidingaansluitingen Liquid UD mm 6.35
  Gas UD mm 12.7
  Afvoer UD mm 18
  Thermische isolatie Zowel vloeistof- als gasleidingen
Verwarmingscapaciteit Min. Btu/u 5,800
  Nom. Btu/u 23,900
  Max. kcal/u 6,880
  Max. Btu/u 27,300
  Nom. kW 7.0
  Min. kW 1.7
  Nom. kcal/u 6,020
  Min. kcal/u 1,460
  Max. kW 8.0
Pto (Thermostat off) W 42.0
Opgenomen vermogen Koelen Min. kW 0.440
    Nom. kW 1.990
    Max. kW 2.400
  Verwarmen Max. kW 2.810
    Min. kW 0.400
    Nom. kW 2.040
Koud seizoen inbegrepen Ja
Current Nominale bedrijfsstroom - 50Hz Verwarmen A 9.4 (2), 9.0 (3), 8.6 (4)
    Koelen A 9.2 (2), 8.8 (3), 8.4 (4)
Opmerkingen EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU
  220V
  230V
  240V
  Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting