FTXS20K2V1B / RXS20L2V1B FTXS25K2V1B / RXS25L2V1B FTXS35K2V1B / RXS35L2V1B FTXS42K3V1B / RXS42L2V1B FTXS42K2V1B / RXS42L2V1B FTXS50K3V1B / RXS50L2V1B FTXS50K2V1B / RXS50L2V1B
Poff (uitgeschakeld) W 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Koelen Psb (koeling in stand-by) W 1.0 1.0 1.0 1.0 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25        
Luchtontvochtiging Koeling l/u       2.3   2.8  
Seizoensrendement (volgens EN14825) Koelen Pdesign kW 2.00 2.50 3.50 4.20 4.20 5.00 5.00
    Jaarlijks energieverbruik kWu 95 111 164 216 216 257 257
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 7.40 7.90 7.47 6.80 6.80 6.80 6.80
    D voorwaarden (20℃ - 27/19) Pdc kW 1.29 1.28 1.46 2.17 2.17 2.14 2.14
      Opgenomen vermogen kW       0.20   0.19  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.65 12.71 12.51 10.69 10.69 11.10 11.10
    C voorwaarden (25℃ - 27/19) Opgenomen vermogen kW       0.24   0.29  
      Pdc kW 1.22 1.22 1.66 2.09 2.09 2.43 2.43
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 9.32 9.98 9.17 8.80 8.80 8.48 8.48
    A voorwaarden (35°C - 27/19) Opgenomen vermogen kW       1.25   1.51  
      Pdc kW 2.00 2.50 3.50 4.20 4.20 5.00 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.39 4.21 3.89 3.35 3.35 3.32 3.32
    B voorwaarden (30℃ - 27/19) Pdc kW 1.47 1.84 2.58 3.09 3.09 3.68 3.68
      Opgenomen vermogen kW       0.56   0.68  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.99 6.71 6.10 5.47 5.47 5.38 5.38
  Verwarming (gematigd klimaat) Jaarlijks energieverbruik kWu 675 732 1,039 1,334 1,334 1,535 1,535
    Pdesign kW 2.30 2.50 3.60 4.00 4.00 4.60 4.60
    Min. vermogen backupverwarming bij ontwerpvoorwdn kW 0.11 0.15 0.55 0.32 0.32 0.52 0.52
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A++ A++ A++ A+ A+ A+ A+
    TBivalent Pdh (verwarmingsvermogen) kW 2.03 2.21 3.18 3.54 3.54 4.07 4.07
      Opgenomen vermogen kW       1.45   1.72  
      Tbiv (bivalente temperatuur) °C -7 -7 -7 -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.10 3.10 2.85 2.44 2.44 2.36 2.36
    C voorwaarden (7℃) Pdh (verwarmingsvermogen) kW 0.99 1.00 1.25 1.66 1.66 1.62 1.62
      Opgenomen vermogen kW       0.30   0.30  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.96 5.96 6.42 5.59 5.59 5.35 5.35
    TOL TOL (bedrijfstemperatuur) °C -15 -15 -15 -15 -15 -15 -15
      Pdh (beschikbaar verwarmingsvermogen) kW 2.47 2.59 2.84 3.90 3.90 4.11 4.11
      Opgenomen vermogen kW       1.91   1.94  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.52 2.50 2.33 2.04 2.04 2.12 2.12
    A voorwaarden (-7°C) Pdh (verwarmingsvermogen) kW 2.03 2.21 3.18 3.54 3.54 4.07 4.07
      Opgenomen vermogen kW       1.45   1.72  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.10 3.10 2.85 2.44 2.44 2.36 2.36
    D voorwaarden (12℃) Pdh (verwarmingsvermogen) kW 1.32 1.34 1.09 1.84 1.84 1.95 1.95
      Opgenomen vermogen kW       0.28   0.30  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.10 7.10 7.79 6.59 6.59 6.43 6.43
    B voorwaarden (2°C) Opgenomen vermogen kW       0.49   0.56  
      Pdh (verwarmingsvermogen) kW 1.23 1.35 1.95 2.15 2.15 2.48 2.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.00 5.00 4.95 4.38 4.38 4.44 4.44
Koelcapaciteit Nom. Btu/u 6,800 8,500 11,900 14,300 (2) 14,300 17,100 (2) 17,100
  Min. kW 1.3 1.3 1.4 1.7 1.7 1.7 1.7
  Nom. kcal/u 1,720 2,150 3,010 3,610 (2) 3,610 4,300 (2) 4,300
  Max. kW 2.8 3.2 4.0 5.0 5.0 5.3 5.3
  Min. kcal/u 1,120 1,120 1,200 1,460 1,460 1,460 1,460
  Min. Btu/u 4,400 4,400 4,800 5,800 5,800 5,800 5,800
  Nom. kW 2.00 2.5 3.5 4.20 (2) 4.20 5.00 (2) 5.00
  Max. Btu/u 9,600 10,900 13,600 17,100 17,100 18,100 18,100
  Max. kcal/u 2,410 2,750 3,440 4,300 4,300 4,560 4,560
Pck (verwarming krukkast) W 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Nominaal energierendement Jaarlijks energieverbruik kWu 215 (0.000) 285 (0.000) 430 (0.000) 627 (0.000) 590 (0.000) 753 (0.000) 705 (0.000)
  Richtlijn Energielabels Verwarming A A A A A A A
  Nominal efficiency-=-Cop 4.65 4.39 4.07 3.35 (1) 3.56 3.32 (1) 3.55
Verwarmen Heating-=-Heating cdh degradation heating 0.25 0.25 0.25        
Leidingaansluitingen Liquid UD mm 6.35 6.35 6.35 6.35 6.35 6.35 6.35
  Gas UD mm 9.5 9.5 9.5 12.7 9.5 12.7 12.7
  Afvoer UD mm 18 18 18 18 18 18 18
  Thermische isolatie Zowel vloeistof- als gasleidingen Zowel vloeistof- als gasleidingen Zowel vloeistof- als gasleidingen Zowel vloeistof- als gasleidingen Zowel vloeistof- als gasleidingen Zowel vloeistof- als gasleidingen Zowel vloeistof- als gasleidingen
Verwarmingscapaciteit Min. Btu/u 4,400 4,400 4,800 5,800 5,800 5,800 5,800
  Nom. Btu/u 8,500 9,600 13,600 18,400 (2) 18,400 19,800 (2) 19,800
  Max. kcal/u 3,700 4,040 4,470 5,160 5,160 5,590 5,590
  Max. Btu/u 14,700 16,000 17,700 20,500 20,500 22,200 22,200
  Nom. kW 2.5 2.8 4.00 5.40 (2) 5.40 5.80 (2) 5.80
  Min. kW 1.3 1.3 1.4 1.7 1.7 1.7 1.7
  Nom. kcal/u 2,150 2,410 3,440 4,640 (2) 4,640 4,990 (2) 4,990
  Min. kcal/u 1,120 1,120 1,200 1,460 1,460 1,460 1,460
  Max. kW 4.3 4.7 5.2 6.0 6.0 6.5 6.5
Pto (Thermostat off) W 20.0 21.0 28.0 30.0 30.0 30.0 30.0
Opgenomen vermogen Koelen Min. kW 0.320 0.320 0.350 0.320 0.320 0.350 0.350
    Nom. kW 0.430 0.570 0.860 1.253 (2) 1.180 1.506 (2) 1.410
    Max. kW 0.760 1.000 1.190 2.330 2.330 1.810 1.810
  Verwarmen Max. kW 1.120 1.410 1.460 1.980 1.980 2.000 2.000
    Min. kW 0.310 0.310 0.340 0.400 0.400 0.300 0.300
    Nom. kW 0.530 0.600 0.840 1.310 (2) 1.310 1.450 (2) 1.450
Koud seizoen inbegrepen Ja Ja Ja Ja Ja Ja Ja
Current Nominale bedrijfsstroom - 50Hz Verwarmen A 2.8 (2), 2.7 (3), 2.6 (4) 3.3 (2), 3.2 (3), 3.1 (4) 4.3 (2), 4.1 (3), 3.9 (4) 6.6 (3), 6.3 (4), 6.0 (5) 6.6 (2), 6.3 (3), 6.0 (4) 6.8 (3), 6.5 (4), 6.2 (5) 6.8 (2), 6.5 (3), 6.2 (4)
    Koelen A 2.4 (2), 2.3 (3), 2.2 (4) 3.2 (2), 3.1 (3), 3.0 (4) 4.3 (2), 4.1 (3), 3.9 (4) 6.37 (3), 6.05 (4), 5.84 (5) 6.0 (2), 5.7 (3), 5.5 (4) 7.05 (3), 6.73 (4), 6.41 (5) 6.6 (2), 6.3 (3), 6.0 (4)
Opmerkingen EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU
  220V 220V 220V Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting 220V Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting 220V
  230V 230V 230V 220V 230V 220V 230V
  240V 240V 240V 230V 240V 230V 240V
  Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting 240V Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting 240V Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting
Koelen Cdc (reductie van koeling)       0.25 0.25 0.25 0.25
Verwarmen Cdh (reductie van verwarming)       0.25 0.25 0.25 0.25