EHSX04P30DA3 / ERGA04EAV3 |
EHSX04P50DA3 / ERGA04EAV3 |
EHSX08P30DA3 / ERGA06EAV3 |
EHSX08P50DA3 / ERGA06EAV3 |
EHSX08P30DA3 / ERGA08EAV3 |
EHSX08P50DA3 / ERGA08EAV3 |
Binnenunit |
EHSX04P30DA3 |
EHSX04P50DA3 |
EHSX08P30DA3 |
EHSX08P50DA3 |
EHSX08P30DA3 |
EHSX08P50DA3 |
Verwarmingscapaciteit |
Nom. |
kW |
4.30 (1), 4.60 (2) |
4.30 (1), 4.60 (2) |
6.00 (1), 5.90 (2) |
6.00 (1), 5.90 (2) |
7.50 (1), 7.80 (2) |
7.50 (1), 7.80 (2) |
Koelcapaciteit |
Nom. |
kW |
4.86 (1), 4.52 (2) |
4.86 (1), 4.52 (2) |
5.96 (1), 5.09 (2) |
5.96 (1), 5.09 (2) |
6.25 (1), 5.44 (2) |
6.25 (1), 5.44 (2) |
Opgenomen vermogen |
Verwarmen |
Nom. |
kW |
0.840 (1), 1.26 (2) |
0.840 (1), 1.26 (2) |
1.24 (1), 1.69 (2) |
1.24 (1), 1.69 (2) |
1.63 (1), 2.23 (2) |
1.63 (1), 2.23 (2) |
|
Koelen |
Nom. |
kW |
0.810 (1), 1.36 (2) |
0.810 (1), 1.36 (2) |
1.06 (1), 1.55 (2) |
1.06 (1), 1.55 (2) |
1.16 (1), 1.73 (2) |
1.16 (1), 1.73 (2) |
COP |
5.10 (1), 3.65 (2) |
5.10 (1), 3.65 (2) |
4.85 (1), 3.50 (2) |
4.85 (1), 3.50 (2) |
4.60 (1), 3.50 (2) |
4.60 (1), 3.50 (2) |
EER |
5.98 (1), 3.32 (2) |
5.98 (1), 3.32 (2) |
5.61 (1), 3.28 (2) |
5.61 (1), 3.28 (2) |
5.40 (1), 3.14 (2) |
5.40 (1), 3.14 (2) |
Verwarming van sanitair warm water |
Algemeen |
Aangegevens belastingprofiel |
|
L |
XL |
L |
XL |
L |
XL |
|
Gematigd klimaat |
Energierendementsklasse waterverwarming |
|
A+ |
A |
A+ |
A |
A+ |
A |
Opmerkingen |
(1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) |
(1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) |
|
(2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) |
(2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) |
(2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) |
(2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) |
(2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) |
(2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) |