| ARXP20P5V1B | ARXP25P5V1B | ARXP35P5V1B | |||||
|---|---|---|---|---|---|---|---|
| Afmetingen | Unit | Hoogte | mm | 556 | 556 | 556 | |
| Breedte | mm | 740 | 740 | 740 | |||
| Diepte | mm | 343 | 343 | 343 | |||
| Gewicht | Unit | kg | 24.0 | 24.0 | 26.0 | ||
| Compressor | Type | Hermetisch gesloten swingcompressor | Hermetisch gesloten swingcompressor | Hermetisch gesloten swingcompressor | |||
| Werkbereik | Koelen | Omgeving | Min. | °C DB | -10 | -10 | -10 |
| Max. | °C DB | 48 | 48 | 48 | |||
| Verwarmen | Omgeving | Min. | °CWB | -15 | -15 | -15 | |
| Max. | °CWB | 18 | 18 | 18 | |||
| Geluidsdrukniveau | Koelen | Hoog | dBA | 44.0 | 44.0 | 45.0 | |
| Verwarmen | Hoog | dBA | 45.0 | 45.0 | 46.0 | ||
| Koelmiddel | Type | R-32 | R-32 | R-32 | |||
| Vulling | kg | 0.550 | 0.550 | 0.700 | |||
| Koudemiddel | Vulling | tCO2Eq | 0.370 | 0.370 | 0.480 | ||
| Koelmiddel | GWP | 675.0 | 675.0 | 675.0 | |||
| Leidingaansluitingen | Leidinglengte | Max. | OU - IU | m | 20 | 20 | 20 |
| Bijkomende koelmiddelvulling | kg/m | 0,02 (voor leidinglengte van meer dan 10 m) | 0,02 (voor leidinglengte van meer dan 10 m) | 0,02 (voor leidinglengte van meer dan 10 m) | |||
| Niveauverschil: | IU - OU | Max. | m | 12.0 | 12.0 | 12.0 | |
| Bereik van het energierendement | A+++ ~ D | A+++ ~ D | A+++ ~ D | ||||
| Voeding | Fase | 1~ | 1~ | 1~ | |||
| Spanningsvoeding | Frequentie | Hz | 50 | 50 | 50 | ||
| Spanning | V | 220-240 | 220-240 | 220-240 | |||