| EAVX16S18DA9WG / EPGA11DAV3 | EAVX16S23DA9WG / EPGA11DAV3 | EAVX16S18DA9WG / EPGA14DAV3 | EAVX16S23DA9WG / EPGA14DAV3 | EAVX16S23DA9WG / EPGA16DAV3 | EAVX16S18DA9WG / EPGA16DAV3 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Sanitair warm water | Algemeen | Aangegevens belastingprofiel | L | XL | XL | L | ||||
| Gematigd klimaat | Energierendementsklasse waterverwarming | A | A | A | A | |||||
| COP | 5.15, 3.88 | 5.15, 3.88 | 4.99 (1), 3.65 (2) | 4.99 (1), 3.65 (2) | 4.78 (1), 3.71 (2) | 4.78 (1), 3.71 (2) | ||||
| Binnenunit | EAVX16S18DA9W | EAVX16S23DA9W | EAVX16S18DA9W | EAVX16S23DA9W | EAVX16S23DA9W | EAVX16S18DA9W | ||||
| Koelcapaciteit | Nom. | kW | 11.1 (1), 11.9 (2) | 11.1 (1), 11.9 (2) | 13.5 (1), 11.9 (2) | 13.5 (1), 11.9 (2) | ||||
| EER | 4.75, 3.23 | 4.75, 3.23 | 4.09 (1), 2.99 (2) | 4.09 (1), 2.99 (2) | 3.94 (1), 2.99 (2) | 3.94 (1), 2.99 (2) | ||||
| Verwarmingscapaciteit | Nom. | kW | 14.5 (1), 14.5 (2) | 14.5 (1), 14.5 (2) | 16.5 (1), 15.6 (2) | 16.5 (1), 15.6 (2) | ||||
| Opgenomen vermogen | Koelen | Nom. | kW | 2.72 (1), 3.97 (2) | 2.72 (1), 3.97 (2) | 3.42 (1), 3.97 (2) | 3.42 (1), 3.97 (2) | |||
| Verwarmen | Nom. | kW | 2.91 (1), 3.96 (2) | 2.91 (1), 3.96 (2) | 3.45 (1), 4.21 (2) | 3.45 (1), 4.21 (2) | ||||
| Opmerkingen | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | |||||
| Verwarmingscapaciteit | Nom. | kW | 11.1, 11.3 | 11.1, 11.3 | ||||||
| Koelcapaciteit | Nom. | kW | 10.5, 10.7 | 10.5, 10.7 | ||||||
| Opgenomen vermogen | Verwarmen | Nom. | kW | 2.16, 2.91 | 2.16, 2.91 | |||||
| Koelen | Nom. | kW | 2.21, 3.30 | 2.21, 3.30 | ||||||
| Sanitair warm water van 10°C tot 50°C | Nom. | kWh | 2.67 | 3.08 | ||||||
| Opwarmingstijd van 10°C tot 50°C | uur | 9u20min bij omgevingstemperatuur van 7°C | 9u20min bij omgevingstemperatuur van 7°C | |||||||
| Verwarming van sanitair warm water | Algemeen | Aangegevens belastingprofiel | L | XL | ||||||
| Gematigd klimaat | Energierendementsklasse waterverwarming | A | A | |||||||
| Verwarming | Wateruitlaat gematigd klimaat 55°C | Algemeen | SCOP | 3.32 | 3.32 | |||||
| Seizoensefficiëntieklasse verwarming | A++ | A++ | ||||||||
| Wateruitlaat gematigd klimaat 35°C | Algemeen | SCOP | 4.44 | 4.44 | ||||||
| Seizoensefficiëntieklasse verwarming | A+++ | A+++ | ||||||||