EPSK08ARW1 |
EPSK10ARW1 |
Afmetingen
|
Unit
|
Hoogte
|
mm
|
1,123
|
1,123
|
|
|
Breedte
|
mm
|
1,330
|
1,330
|
|
|
Diepte
|
mm
|
604
|
604
|
Gewicht
|
Unit
|
kg
|
178
|
178
|
Ventilator
|
Luchtdebiet
|
Verwarmen
|
Hoog
|
m³/min
|
75.7
|
75.7
|
|
|
Koelen
|
Hoog
|
m³/min
|
75.7
|
75.7
|
Bedrijfsbereik
|
Koelen
|
Min.
|
°CDB
|
10
|
10
|
|
|
Max.
|
°CDB
|
43
|
43
|
Werkbereik
|
Sanitair warm water
|
Min.
|
°CDB
|
-28
|
-28
|
|
|
Max.
|
°CDB
|
40
|
40
|
Geluidsvermogenniveau
|
Verwarmen
|
Nom.
|
dBA
|
45 (1)
|
47 (1)
|
|
Koelen
|
Nom.
|
dBA
|
53 (2)
|
53.2 (2)
|
Geluidsdrukniveau
|
Verwarmen
|
Nom.
|
dBA
|
32.4 (1)
|
32.8 (1)
|
|
Koelen
|
Nom.
|
dBA
|
37.2 (2)
|
37.3 (2)
|
Koelmiddel
|
Type
|
|
R-290
|
R-290
|
|
GWP
|
|
3
|
3
|
Koudemiddel
|
Vulling
|
tCO2Eq
|
0.003
|
0.003
|
Koelmiddel
|
Vulling
|
kg
|
1
|
1
|
Leidingaansluitingen
|
Niveauverschil:
|
IU - OU
|
Max.
|
m
|
10
|
10
|
Voeding
|
Naam
|
|
W1
|
W1
|
|
Fase
|
|
3~
|
3~
|
Spanningsvoeding
|
Frequentie
|
Hz
|
50
|
50
|
|
Spanning
|
V
|
400
|
400
|
Stroom
|
Aanbevolen zekeringen
|
A
|
16
|
16
|
Opmerkingen
|
(1) - Gemeten bij LWC 47-55°C; Ta DB/NB 7°C/6°C.
|
(1) - Gemeten bij LWC 47-55°C; Ta DB/NB 7°C/6°C.
|
|
(2) - Gemeten bij LWC 12-7°C; Ta 35 °C.
|
(2) - Gemeten bij LWC 12-7°C; Ta 35 °C.
|
|
(3) - Leidingen van 1 1/4” ter plaatse
|
(3) - Leidingen van 1 1/4” ter plaatse
|
|
(4) - Leidingen van 1 1/2” ter plaatse
|
(4) - Leidingen van 1 1/2” ter plaatse
|