| ETSX12P30EF / EPRA08EAV3 | ETSX12P50EF / EPRA08EAV3 | ETSX12P30EF / EPRA10EAV3 | ETSX12P50EF / EPRA10EAV3 | ETSX12P30EF / EPRA12EAV3 | ETSX12P50EF / EPRA12EAV3 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Indoor unit | ETSX12P30EF | ETSX12P50EF | ETSX12P30EF | ETSX12P50EF | ETSX12P30EF | ETSX12P50EF | ||||
| Verwarmingscapaciteit | Nom. | kW | 6.17 (1) | 6.17 (1) | 6.17 (1) | 6.17 (1) | 6.17 (1) | 6.17 (1) | ||
| Koelcapaciteit | Nom. | kW | 6.81 (2) | 6.81 (2) | 7.97 (2) | 7.97 (2) | 8.62 (2) | 8.62 (2) | ||
| Opgenomen vermogen | Verwarmen | Nom. | kW | 1.25 (1) | 1.25 (1) | 1.25 (1) | 1.25 (1) | 1.25 (1) | 1.25 (1) | |
| Koelen | Nom. | kW | 2.15 (2) | 2.15 (2) | 2.66 (2) | 2.66 (2) | 2.96 (2) | 2.96 (2) | ||
| COP | 4.92 (3) | 4.92 (3) | 4.92 (3) | 4.92 (3) | 4.92 (3) | 4.92 (3) | ||||
| EER | 3.17 (2) | 3.17 (2) | 3 | 3 | 2.91 (2) | 2.91 (2) | ||||
| Verwarming van sanitair warm water | Algemeen | Aangegevens belastingprofiel | L | XL | L | XL | L | XL | ||
| Gematigd klimaat | Energierendementsklasse waterverwarming | A+ | A+ | A+ | A+ | A+ | A+ | |||
| Verwarming | Wateruitlaat gematigd klimaat 55°C | Algemeen | SCOP | 3.47 | 3.47 | 3.48 | 3.48 | 3.48 | 3.48 | |
| Seizoensefficiëntieklasse verwarming | A++ | A++ | A++ | A++ | A++ | A++ | ||||
| Wateruitlaat gematigd klimaat 35°C | Algemeen | SCOP | 4.79 | 4.79 | 4.82 | 4.82 | 4.82 | 4.82 | ||
| Seizoensefficiëntieklasse verwarming | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | ||||
| Opmerkingen | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Toestand 1: koelen Ta 35°C - LWE 18°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | (2) - Toestand 2: koelen Ta 35°C - LWE 7°C (DT = 5°C); verwarmen Ta DB/NB 7°C/6°C - LWC 45°C (DT = 5°C) | |||||
| (3) - Voorwaarde: Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Voorwaarde: Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Voorwaarde: Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Voorwaarde: Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Voorwaarde: Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | (3) - Voorwaarde: Ta DB/NB 7°C/6°C - LWC 35°C (DT = 5°C) | |||||
| (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental | (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental | (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental | (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental | (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental | (4) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) met pomp aan volledig toerental | |||||