| FTXS20K2V1B / RXS20L2V1B | FTXS25K2V1B / RXS25L2V1B | FTXS35K2V1B / RXS35L2V1B | FTXS42K2V1B / RXS42L2V1B | FTXS42K3V1B / RXS42L2V1B | FTXS50K2V1B / RXS50L2V1B | FTXS50K3V1B / RXS50L2V1B | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Koelcapaciteit | Min. | kW | 1.3 | 1.3 | 1.4 | 1.7 | 1.7 | |||
| Max. | kW | 2.8 | 3.2 | 4.0 | 5.0 | 5.3 | ||||
| Nom. | kW | 2.00 | 2.5 | 3.5 | 4.20 | 5.00 | ||||
| Leidingaansluitingen | Vloeistof | Buitendiameter | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | ||
| Gas | Buitendiameter | mm | 9.5 | 9.5 | 9.5 | 9.5 | 12.7 | |||
| Afvoer | UD | mm | 18 | 18 | 18 | 18 | 18 | |||
| Nominaal energierendement | Jaarlijks energieverbruik | kWu | 215 | 285 | 430 | 590 | 705 | |||
| EER | 4.65 | 4.39 | 4.07 | 3.56 | 3.55 | |||||
| COP | 4.72 | 4.67 | 4.76 | 4.12 | 4.00 | |||||
| Richtlijn Energielabels | Koeling | A | A | A | A | A | ||||
| Verwarming | A | A | A | A | A | |||||
| Verwarmingscapaciteit | Nom. | kW | 2.5 | 2.8 | 4.00 | 5.40 | 5.80 | |||
| Min. | kW | 1.3 | 1.3 | 1.4 | 1.7 | 1.7 | ||||
| Max. | kW | 4.3 | 4.7 | 5.2 | 6.0 | 6.5 | ||||
| Opmerkingen | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | |||
| (2) - 220V | (2) - 220V | (2) - 220V | (2) - 220V | (2) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (2) - 220V | (2) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | ||||
| (3) - 230V | (3) - 230V | (3) - 230V | (3) - 230V | (3) - 220V | (3) - 230V | (3) - 220V | ||||
| (4) - 240V | (4) - 240V | (4) - 240V | (4) - 240V | (4) - 230V | (4) - 240V | (4) - 230V | ||||
| (5) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (5) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (5) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (5) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (5) - 240V | (5) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (5) - 240V | ||||
| Buitenunit | RXS42L | RXS50L | ||||||||
| Koelcapaciteit | Min. | kW | 1.7 | 1.7 | ||||||
| Nom. | kW | 4.20 | 5.00 | |||||||
| Max. | kW | 5.0 | 5.3 | |||||||
| Verwarmingscapaciteit | Min. | kW | 1.7 | 1.7 | ||||||
| Nom. | kW | 5.40 | 5.80 | |||||||
| Max. | kW | 6.0 | 6.5 | |||||||
| Nominaal rendement | EER | 3.35 | 3.32 | |||||||
| COP | 4.12 | 4.00 | ||||||||
| Jaarlijks energieverbruik | kWu | 627 | 753 | |||||||
| Nominaal energierendement | Richtlijn Energielabels | Koeling | A | A | ||||||
| Verwarming | A | A | ||||||||
| Leidingaansluitingen | Afvoer | UD | mm | 18 | 18 | |||||
| Gas | Buitendiameter | mm | 12.7 | 12.7 | ||||||
| Vloeistof | Buitendiameter | mm | 6.35 | 6.35 | ||||||
| Koeling | Energieklasse | A++ | A++ | |||||||
| Vermogen | Pdesign | kW | 4.20 | 5.00 | ||||||
| SEER | 6.80 | 6.80 | ||||||||
| Jaarlijks energieverbruik | kWu/a | 216 | 257 | |||||||
| Verwarming (gematigd klimaat) | Energieklasse | A+ | A+ | |||||||
| Vermogen | Pdesign | kW | 4.00 | 4.60 | ||||||
| SCOP/A | 4.20 | 4.20 | ||||||||
| Jaarlijks energieverbruik | kWu/a | 1334 | 1535 | |||||||