| FVXG25K2V1B / RXG25K2V1B | FVXG25K2V1B / RXG25K3V1B | FVXG35K2V1B / RXG35K2V1B | FVXG35K2V1B / RXG35K3V1B | FVXG50K2V1B / RXG50K2V1B | FVXG50K2V1B / RXG50K3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|
| Koelcapaciteit | Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | |
| Max. | kW | 3.0 | 3.0 | 3.8 | 3.8 | 5.6 | 5.6 | ||
| Nom. | kW | 2.5 (3) | 2.5 (2) | 3.5 (3) | 3.5 (2) | 5.0 (3) | 5.0 (2) | ||
| Leidingaansluitingen | Vloeistof | Buitendiameter | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 |
| Gas | Buitendiameter | mm | 9.5 | 9.5 | 9.5 | 9.5 | 12.7 | 12.7 | |
| Afvoer | UD | mm | 18 | 18 | 18 | 18 | 18 | 18 | |
| Nominaal energierendement | Jaarlijks energieverbruik | kWh | 275 | 275 | 475 | 475 | 760 | 760 | |
| EER | 4.55 | 4.55 | 3.68 | 3.68 | 3.29 | 3.29 | |||
| COP | 4.36 | 4.36 | 3.72 | 3.72 | 3.67 | 3.67 | |||
| Richtlijn Energielabels | Koeling | A | A | A | A | A | A | ||
| Verwarming | A | A | A | A | A | A | |||
| Verwarmingscapaciteit | Nom. | kW | 3.4 (4) | 3.4 (3) | 4.5 (4) | 4.5 (3) | 5.8 (4) | 5.8 (3) | |
| Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | ||
| Max. | kW | 4.5 | 4.5 | 5.0 | 5.0 | 8.1 | 8.1 | ||
| Opmerkingen | (1) - Energielabel: schaalverdeling van A (meest efficiënt) tot G (minst efficiënt) | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - Energielabel: schaalverdeling van A (meest efficiënt) tot G (minst efficiënt) | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - Energielabel: schaalverdeling van A (meest efficiënt) tot G (minst efficiënt) | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | |||
| (2) - Jaarlijks energieverbruik: op basis van een gemiddelde van 500 bedrijfsuren per jaar bij vollast (nominale omstandigheden) | (2) - Koelen: binnentemp. 27°CDB, 19°CNB; buitentemp. 35°CDB, 24°CNB | (2) - Jaarlijks energieverbruik: op basis van een gemiddelde van 500 bedrijfsuren per jaar bij vollast (nominale omstandigheden) | (2) - Koelen: binnentemp. 27°CDB, 19°CNB; buitentemp. 35°CDB, 24°CNB | (2) - Jaarlijks energieverbruik: op basis van een gemiddelde van 500 bedrijfsuren per jaar bij vollast (nominale omstandigheden) | (2) - Koelen: binnentemp. 27°CDB, 19°CNB; buitentemp. 35°CDB, 24°CNB | ||||
| (3) - Koelen: binnentemp. 27°CDB, 19°CNB; buitentemp. 35°CDB, 24°CNB | (3) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (3) - Koelen: binnentemp. 27°CDB, 19°CNB; buitentemp. 35°CDB, 24°CNB | (3) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (3) - Koelen: binnentemp. 27°CDB, 19°CNB; buitentemp. 35°CDB, 24°CNB | (3) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | ||||
| (4) - Koelen: binnentemp. 27°CDB, 19°CWB; buitentemperatuur. 35°CDB, 24°CWB | (4) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (4) - Koelen: binnentemp. 27°CDB, 19°CWB; buitentemperatuur. 35°CDB, 24°CWB | (4) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (4) - Koelen: binnentemp. 27°CDB, 19°CWB; buitentemperatuur. 35°CDB, 24°CWB | (4) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | ||||
| (5) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (5) - 220V | (5) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (5) - 220V | (5) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (5) - 220V | ||||
| (6) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (6) - 230V | (6) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (6) - 230V | (6) - Verwarmen: binnentemp. 20°CDB; buitentemp. 7°CDB, 6°CWB | (6) - 230V | ||||
| (7) - 220V | (7) - 240V | (7) - 220V | (7) - 240V | (7) - 220V | (7) - 240V | ||||
| (8) - 230V | (8) - Wanneer aangesloten op een multisysteem buitenunit, raadpleeg dan de karakteristieken van de multibuitenunit die aangesloten moet worden. | (8) - 230V | (8) - Wanneer aangesloten op een multisysteem buitenunit, raadpleeg dan de karakteristieken van de multibuitenunit die aangesloten moet worden. | (8) - 230V | (8) - Wanneer aangesloten op een multisysteem buitenunit, raadpleeg dan de karakteristieken van de multibuitenunit die aangesloten moet worden. | ||||
| (9) - 240V | (9) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (9) - 240V | (9) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (9) - 240V | (9) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | ||||
| (10) - Wanneer aangesloten op een multisysteem buitenunit, raadpleeg dan de karakteristieken van de multibuitenunit die aangesloten moet worden. | (10) - Wanneer aangesloten op een multisysteem buitenunit, raadpleeg dan de karakteristieken van de multibuitenunit die aangesloten moet worden. | (10) - Wanneer aangesloten op een multisysteem buitenunit, raadpleeg dan de karakteristieken van de multibuitenunit die aangesloten moet worden. | |||||||
| (11) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (11) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (11) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | |||||||