| FVXG25K2V1B / RXLG25M2V1B | FVXG35K2V1B / RXLG35M2V1B | ||||
|---|---|---|---|---|---|
| Outdoor unit | RXLG25M | RXLG35M | |||
| Koelcapaciteit | Min. | kW | 1.2 | 1.4 | |
| Nom. | kW | 2.5 | 3.5 | ||
| Max. | kW | 5.1 | 5.6 | ||
| Verwarmingscapaciteit | Min. | kW | 1.0 | 1.1 | |
| Nom. | kW | 4.5 | 5.6 | ||
| Max. | kW | 6.5, 3.5 | 7.0, 4.0 | ||
| Nominaal rendement | EER | 3.52 | 3.43 | ||
| COP | 3.88 | 3.61 | |||
| Jaarlijks energieverbruik | kWu | 355 | 510 | ||
| Nominaal energierendement | Richtlijn Energielabels | Koeling | A | A | |
| Verwarming | A | A | |||
| Leidingaansluitingen | Afvoer | UD | mm | 18 | 18 |
| Gas | Buitendiameter | mm | 9.5 | 9.5 | |
| Vloeistof | Buitendiameter | mm | 6.35 | 6.35 | |
| Koeling | Energieklasse | A++ | A++ | ||
| Vermogen | Pdesign | kW | 2.50 | 3.50 | |
| SEER | 6.99 | 6.59 | |||
| Jaarlijks energieverbruik | kWu/a | 131 | 186 | ||
| Verwarming (gematigd klimaat) | Energieklasse | A+ | A+ | ||
| Vermogen | Pdesign | kW | 3.00 | 3.40 | |
| SCOP/A | 4.25 | 4.01 | |||
| Jaarlijks energieverbruik | kWu/a | 988 | 1187 | ||
| Opmerkingen | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | (1) - EER/COP volgens Eurovent 2012, alleen voor gebruik buiten de EU | |||
| (2) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | (2) - Nominaal rendement: koeling tegen 35°/27° nominale belasting, verwarming tegen 7°/20° nominale belasting | ||||
| (3) - 220V | (3) - 220V | ||||
| (4) - 230V | (4) - 230V | ||||
| (5) - 240V | (5) - 240V | ||||
| (6) - Voor minimaal verwarmingsvermogen, ventilator van binnenunit instellen op SL-stand | (6) - Voor minimaal verwarmingsvermogen, ventilator van binnenunit instellen op SL-stand | ||||
| (7) - Maximaal verwarmingsvermogen bij buitentemperatuur van -15°C | (7) - Maximaal verwarmingsvermogen bij buitentemperatuur van -15°C | ||||